Thermal Oil Pumps
Horizontal, single-stage, end suction centrifugal pumps designed for circulating heat transfer oils in industrial heat transfer systems. The volute casing, closed impeller and air-cooled design are suited to the operating conditions of high-temperature oil circuits.
With a suitable liquid, materials and sealing, they can be used at operating temperatures up to +350 °C. The main pump dimensions comply with EN 733, and the suction and discharge flanges with EN 1092-2 / PN 16.
The back pull-out design gives access to the bearing and rotating assembly without disconnecting the volute casing from the pipework. With the optional spacer coupling, the rotating assembly can also be removed without taking off the motor.
Suitable for the transfer of heat transfer oils and low-viscosity industrial oils that contain no abrasive particles.
The compatibility of the oil with the pump materials and sealing elements must be assessed. The temperature-dependent viscosity, density and vapour pressure of the oil are taken into account when selecting the pump, the motor and the suction conditions.
The +350 °C temperature capability of the pump does not mean that every heat transfer oil can be used at this temperature. The limits of use stated by the oil manufacturer must also be observed.
For high-temperature heat transfer circuits, with suitable oil, materials and sealing.
The thermal layout of the pump is based on transferring the heat generated to the surrounding air.
The bearing and rotating assembly can be accessed while the casing stays connected to the pipework. With the spacer coupling option, the motor can stay in place.
Which industries is it used in?
ECO Thermal Oil Pumps are used in industrial heating systems where heat is carried to process equipment by a heat transfer liquid. The scope of application is the heat transfer oil circuit of the plant concerned.
They can be used to circulate oil through process equipment and auxiliary heating circuits operating with heat transfer oil. The properties of the oil and the temperature and pressure conditions of the circuit are assessed during selection.
They can be used in thermal oil heating systems on ships and in shore facilities. The material, installation and, where applicable, classification requirements of the application are assessed separately within the project.
They can be used for circulation in power generation and heat recovery systems that use heat transfer oil. The pump is selected according to the temperature range and hydraulic requirements of the circuit concerned.
They can be used in thermal oil circuits that indirectly heat ovens, dryers and other process equipment. This does not cover hygienic transfer applications where the pump is in direct contact with the food product.
They provide circulation in central and industrial temperature control systems that use heat transfer oil. Suitability is assessed according to the properties of the oil in the circuit and the operating temperatures.
They can be used in thermal oil circuits that indirectly heat reactors, stirred tanks, dryers and heat exchangers. They are not intended for the direct transfer of chemical process products.
They can be used for circulation in drying and auxiliary process heating systems that use heat transfer oil. They are not suitable for the transfer of sludge, slurry or ore suspensions.
They can be used in thermal oil circuits for the indirect heating of tanks and process equipment. Suitability for the transfer of crude oil, fuels or volatile hydrocarbons must be assessed separately.
Rotate the pump by dragging or with the arrow keys; examine it from every angle.

Designed for high-temperature applications
ECO Thermal Oil Pumps have been developed for industrial circuits in which heat transfer oils are circulated. The casing, bearing and sealing arrangement are selected by considering the liquid temperature and operating conditions together.
The operating temperature of the pump must be considered together with the permissible temperature of the oil used and the pressure-temperature limits of the pump.
Air-cooled design
Cooling is provided by air. Air circulation around the pump and the conditions at the installation site are therefore important for transferring heat to the surrounding air.
Surfaces intended for cooling, and the areas around the bearings and the seal, must not be covered or insulated except as specified in the manufacturer’s installation instructions. When planning the thermal insulation of the pipework, the cooling requirements of the pump must be maintained.
Hydraulic design
The single-stage volute casing and closed impeller allow oils of suitable viscosity to be transferred and circulated. Balancing holes in the impeller help to reduce the axial forces generated during operation.
The pump is selected on the basis of flow and head, together with the viscosity and density of the oil at operating temperature, the power requirement and the suction conditions.
Cold and hot operating conditions
The viscosity of heat transfer oil changes with temperature. Hydraulic behaviour and power requirement may differ between cold start-up conditions and normal operating temperature.
For this reason, the pump and motor should be selected not only for the hot operating point but also with the expected start-up conditions in mind.
Bearings and lubrication
As standard, grease-lubricated rolling bearings are used. The choice of lubricant, the quantity and the maintenance intervals are given in the maintenance instructions for the pump concerned.
Bearing operating temperature, vibration and noise are part of the maintenance checks.
Shaft sealing
As standard, a single mechanical seal suitable for high-temperature service is used. The seal is selected according to the properties of the oil and the operating conditions of the pump.
Soft packing can be used on request, subject to an assessment of its suitability for the application. However, it does not replace the standard mechanical seal in every application.
Back pull-out design
The bearing bracket, seal housing, pump shaft and impeller can be removed while the volute casing stays connected to the pipework. This means the suction and discharge connections do not have to be disconnected when servicing these parts.
Easy access to the internal parts makes inspection and maintenance of the seal and rotating assembly easier.
Spacer coupling option
With the optional spacer coupling, the rotating assembly of the pump can be removed without taking off the electric motor.
This option makes maintenance access easier in plants where lifting and repositioning the motor is difficult. The service clearance needed to remove the rotating assembly should be allowed for at the layout stage.
Main dimensions and flange connections
The main pump dimensions comply with EN 733. The suction and discharge flanges are arranged in accordance with EN 1092-2 / PN 16.
Even with PN 16 flanges, the 16 bar casing pressure does not apply at every temperature. The permissible casing pressure must be determined from the pressure-temperature limits of the material concerned.
Impeller balancing and direction of rotation
Impellers are balanced statically or dynamically in accordance with ISO 21940-11 balance quality grade G 6.3.
The direction of rotation is clockwise when viewed from the motor end.
Installation and thermal expansion
The pump-motor unit must be installed in accordance with the installation drawing of the relevant model. Thermal expansion of the hot oil pipework and piping loads must be accommodated so that excessive forces are not transmitted to the pump flanges.
When aligning the coupling and checking the connections, the differences between cold installation and hot operating conditions must be taken into account. Sufficient clearance must be left around the unit for air circulation and maintenance access.
Operating limits and pump selection
The permissible operating pressure depends on the temperature, the casing material and the selected sealing arrangement. The maximum flow, head, speed and temperature values do not describe a single operating point that applies to all models at the same time.
When assessing the pressure acting on the casing, the suction pressure and the pressure rise generated by the pump must be considered together. The closed-valve condition is also part of this assessment.
Final selection should be based on the performance curves, the properties of the oil, the suction conditions and the pressure-temperature limits considered together.
- ECO GHO
- Pump type
- 100
- Discharge flange diameter (DN-mm)
- 250
- Nominal impeller diameter (mm)
- XXX
- Special application
Operating ranges and model range
The envelopes show the design range of the series. For a specific duty point the hydraulics are verified by CFD analysis and delivered with the curve sheet, dimensions and, where required, a test report.
24 norm + 6 complementary
The permissible casing pressure depends on the operating temperature and the material selected. The +350 °C temperature limit and the 16 bar pressure value do not apply at the same time; selection must be based on the relevant pressure-temperature limits.
1450 rpm1450 and 2900 rpm (23)Ccomplementary model (6)
StandardOptional—Not specified
| Material | Material no. | Volute casing | Casing cover | Impeller | Shaft | Bearing housing |
|---|---|---|---|---|---|---|
| Cast materials | ||||||
| Grey cast iron | 0.6025 | — | — | — | — | |
| Ductile cast iron | 0.7040 | — | ||||
| Cr-Ni-Mo stainless cast steel | 1.4408 | — | ||||
| Steel materials | ||||||
| Martensitic stainless steel | 1.4021 | — | — | — | — | |
| Cr-Ni-Mo stainless steel · low carbon | 1.4404 | — | — | — | — | |
Mechanical seal: EN 12756
Cr: Chromium · Ni: Nickel · Mo: Molybdenum.
| Material description | Material no. | EN / DIN designation | AISI / SAE / ASTM equivalent* |
|---|---|---|---|
| Grey cast iron | 0.6025 | EN-GJL-250 (GG25) | A48 Class 40B |
| Ductile cast iron | 0.7040 | EN-GJS-400-15 (GGG40) | A536 60-40-18 |
| Cr-Ni-Mo stainless cast steel | 1.4408 | GX5CrNiMo19-11-2 | A351 CF8M |
| Martensitic stainless steel | 1.4021 | X20Cr13 | A276 Type 420 |
| Cr-Ni-Mo stainless steel · low carbon | 1.4404 | X2CrNiMo17-12-2 | A276 Type 316L |
* Equivalents are for reference only; materials to different standards may not be identical in every chemical, mechanical and heat treatment requirement. The relevant product standard and material certificate govern the final selection.
ECO Thermal Oil Pumps design package
A production-ready series of 30 models: 24 norm and 6 complementary. The package covers hydraulic design, pattern drawings and test verification, giving a manufacturer the design basis to produce the series under its own brand.
WHAT THE PACKAGE INCLUDES
3D impeller and volute models, curve sheets for 30 models. Parametric 3D models built in Siemens NX and SolidWorks.
Dimension drawings, assembly and sectional drawings, parts list. Stress, vibration and fatigue assessments of shaft, impeller and casing components.
Material options and equivalents, flange dimensions. EN 733 main dimensions, EN 1092-2 / PN 16 flanges, ISO 21940-11 G 6.3 impeller balancing.
Comparison of design and test results using ANSYS CFX / Fluent-based CFD analyses; test and verification reports depending on project scope.
Manufacturing drawings, casting pattern and core data, manufacturing documentation. Work is carried out on a project basis or under an ongoing outsourced R&D model.
ECO Types 10
ECO EN 733 Norm Centrifugal Pumps02
ECO EN 733 Norm Centrifugal Pumps - Vertical03
ECO Sump Pumps04
ECO EN 733 Close-Coupled Pumps05
ECO EN 733 Close-Coupled Pumps - Vertical06
ECO In-Line Centrifugal Pumps07
ECO In-Line Centrifugal Pumps - With Separate Bearing Bracket08THIS PAGE
ECO Thermal Oil Pumps09
ECO EN ISO 2858 Chemical Process Pumps10
ECO Hot Water and Geothermal Pumps