TREN
Our pump design portfolio
Pump engineering for different applications
We develop pump designs across nine product families, from water supply to industrial processes and from fire protection systems to energy recovery.
Istanbul - Türkiye · 41.0082° N, 28.9784° EGiresun - Türkiye · 40.9175° N, 38.3837° E
Technical data
Design ranges by family
9product families
11series
34types
746models
Pump
7
25
655
Booster set
2
5
15
Fire
2
4
76
End Suction Centrifugal Pumps
Discharge flangeDN32 – DN300
Capacityup to 1930 m³/h
Headup to 160 m
Speedup to 3600 rpm
Operating temperature-10 °C to +350 °C
Casing pressure (Pmax)10 – 40 bar
Double Suction Centrifugal Pumps
Discharge flangeDN65 – DN800
Capacityup to 15,500 m³/h
Headup to 225 m
Speedup to 2900 rpm
Operating temperature-10 °C to +110 °C
Casing pressure (Pmax)16 / 25 bar
Multistage Centrifugal Pumps
Discharge flangeDN32 – DN300
Capacityup to 1700 m³/h
Headup to 550 m
Speedup to 2900 rpm
Operating temperature-10 °C to +140 °C
Casing pressure (Pmax)30 / 63 bar
Waste Water & Submersible Pumps
Discharge flangeDN40 – DN400
Capacityup to 4480 m³/h
Headup to 100 m
Speedup to 2900 rpm
Operating temperature-10 °C to +110 °C
Casing pressure (Pmax)10 – 16 bar
Vertical Line Shaft Mixed Flow Pumps
Discharge flangeDN200 – DN2200
Capacityup to 27,370 m³/h
Headup to 275 m
Speedup to 2900 rpm
Operating temperatureup to 105 °C
Casing pressure (Pmax)27 bar
API 610 / ISO 13709 Process Pumps
Discharge flangeDN25 – DN400 / NPS 1″ – 16″
Capacityup to 4200 m³/h
Headup to 270 m
Speedup to 3600 rpm
Operating temperature-70 °C to +450 °C
Casing pressure (Pmax)110 bar
Pump as Turbine [HydroPaT]
Target electrical powerup to 2880 kW
Net head (H)10 – 200 m
Target flow range30 – 15,500 m³/h
Generator options4 / 6 / 8 poles
Fire Fighting Pumps
StandardNFPA 20 · designed to UL / FM requirements
Capacity25 – 5000 GPM (5.7 – 1136 m³/h)
Head30 – 170 m
Casing pressure (Pmax)10 – 30 bar
Speedup to 3000 rpm
Booster Sets
Capacityup to 300 m³/h
Headup to 180 m
Speedup to 2900 rpm
Operating temperature0 °C to +70 °C
Casing pressure (Pmax)10 / 16 / 25 bar






![Pump as Turbine [HydroPaT]](../assets/pg-pat-en.jpg)