ECO Hot Water and Geothermal Pumps
Pumps/10 / 10
SINGLE-STAGE END SUCTION

ECO Hot Waterand Geothermal Pumps

DN32 – DN250Discharge flange
up to 1500 m³/hCapacity
up to 160 mHead
up to 2900 rpmSpeed
up to +230 °COperating temperature
25 / 40 barCasing pressure (Pmax)
Product Description

Hot Water and Geothermal Pumps

Horizontal, single-stage, end suction centrifugal pumps designed for the transfer and circulation of hot water and suitable geothermal liquids. With a closed impeller, heavy-duty shaft and oil-lubricated bearings, they are built for the requirements of high-temperature processes.

The centreline-mounted casing helps to reduce the effect of temperature-related expansion on pump-motor alignment. With suitable materials and sealing, they can be used at operating temperatures up to +230 °C.

Thanks to the back pull-out design, the bearing bracket, seal housing, pump shaft and impeller can be removed while the volute casing stays connected to the pipework. With the optional spacer coupling, the rotating assembly can also be removed without moving the motor.

Liquids handled

Designed especially for hot water and geothermal water applications. The properties of the liquid must be compatible with the pump materials and sealing arrangement.

In geothermal applications, the chemical composition, dissolved gases, solids content and scaling tendency of the liquid must be assessed during selection. Because the composition of source waters differs, not every geothermal water can be pumped with the same materials and seal arrangement.

The pressure conditions that keep high-temperature water in the liquid phase are part of the suction and operating assessment of the pump.

Standards and design
EN 1092-2 / PN 25Reference suction and discharge flange arrangement
ISO 21940-11 G 6.3Impeller balancing
01Centreline-mounted design

Helps to reduce the effect of temperature-related casing expansion on shaft and coupling alignment.

02up to +230 °C

For high-temperature water applications, with suitable materials, pressure rating and sealing.

03Easy maintenance access

The bearing and rotating assembly can be accessed while the casing stays connected to the pipework. With the spacer coupling option, the motor can stay in place.

Applications

Which industries is it used in?

5applications

ECO Hot Water and Geothermal Pumps are used in plants that require the transfer and circulation of high-temperature water. For geothermal applications, materials and seals are selected according to the properties of the source liquid.

Power Plant01

Used in the cooling, service and auxiliary liquid circuits of power generation plants. Pump selection is based on the liquid, temperature and pressure conditions of the circuit concerned.

Heating & Cooling02

Used in the circulation circuits of central and industrial heating, cooling and air-conditioning systems. The type of liquid, its additives and the operating temperature are taken into account when selecting materials and sealing.

Chemical Industry03

Used in the hot water circuits of chemical plants. The compatibility of casing, impeller and sealing materials with the liquid is assessed separately for each application.

Petroleum Industry04

Used in the hot water circuits of petroleum facilities. Hydrocarbon transfer and applications requiring special standards or explosive-atmosphere compliance are assessed separately.

Water Supply and Treatment05

Used in the hot water transfer and pressure boosting circuits of water supply, distribution and treatment plants. The pump type is selected according to the temperature and quality of the water.

360° view

Rotate the pump by dragging or with the arrow keys; examine it from every angle.

ECO Hot Water and Geothermal PumpsECO Hot Water and Geothermal pump
Technical features
01

Centreline-mounted casing

The casing is supported at points close to the shaft centreline. This reduces the effect of casing expansion caused by temperature changes on the shaft axis and coupling alignment.

Correct installation, control of piping loads and coupling alignment are nevertheless required.

02

Hydraulic design

The single-stage volute casing and closed impeller are used for the transfer and circulation of hot water and suitable geothermal liquids. Balancing holes in the impeller help to reduce the axial forces generated during operation.

The pump is selected on the basis of flow and head, together with the liquid temperature, density, vapour pressure, suction conditions and power requirement.

03

Shaft not in contact with the liquid

The heavy-duty pump shaft is arranged so that it does not come into direct contact with the pumped liquid.

The suitability of the other wetted parts, gaskets and sealing elements must be assessed separately. Although the shaft is not in contact with the liquid, the pump must not be run dry.

04

Bearings and lubrication

As standard, oil-lubricated rolling bearings are used. The type of oil, oil level and change intervals are determined by the maintenance instructions of the relevant pump.

Bearing operating temperature, vibration and noise are part of the maintenance checks. The lubrication arrangement must be assessed together with the operating conditions of the pump.

05

Shaft sealing options

Depending on the liquid properties and operating conditions, a single, double or cartridge mechanical seal or soft packing can be used.

“Cartridge” describes how the seal is assembled and can be combined with a single or double arrangement. The seal is selected taking into account temperature, pressure, liquid composition and the sealing requirements of the process.

06

Seal cooling

Where required, seal cooling supplied from an external source can be provided. The properties of the cooling liquid and the supply conditions are determined by the selected seal arrangement.

The need for external cooling depends on the application.

07

Casing sealing

Flat gaskets, seated so that they cannot be displaced under pressure, are used at the casing joint.

The gasket material must be selected to suit the chemical properties, operating temperature and pressure of the liquid.

08

Back pull-out design

The bearing bracket, seal housing, pump shaft and impeller can be removed while the volute casing stays connected to the pipework. This means the suction and discharge connections do not have to be disconnected when servicing these parts.

This design makes it easier to reach the seal and rotating assembly, which helps in planning maintenance work.

09

Spacer coupling option

With the optional spacer coupling, the rotating assembly can be removed without moving the electric motor.

This option makes maintenance access easier in plants where lifting and repositioning the motor is difficult. The service clearance needed to remove the rotating assembly should be allowed for at the layout stage.

10

Flange connections and pressure selection

In the reference connection arrangement, the suction and discharge flanges comply with EN 1092-2 / PN 25.

For applications requiring a casing pressure of 40 bar, the suitability of the flanges, gaskets, fasteners and seal arrangement must be determined together with the casing. The reference PN 25 connection arrangement is not automatically suitable for 40 bar operation; EN 1092-2 / PN 40 flange dimensions are defined for this pressure.

11

Impeller balancing and direction of rotation

Impellers are balanced statically or dynamically in accordance with ISO 21940-11 balance quality grade G 6.3.

The direction of rotation is clockwise when viewed from the motor end.

12

Suction conditions and hot liquid selection

In high-temperature water applications, suction pressure, the vapour pressure of the liquid and suction line losses must be assessed together. The NPSH available from the installation must exceed the NPSH required by the pump by a suitable margin.

With geothermal liquids, gas release and scale formation must also be taken into account during selection. The exact operating conditions must be determined from the liquid analysis and plant data.

13

Installation and thermal expansion

The pump-motor unit must be installed and secured in accordance with the installation drawing of the relevant model. Thermal expansion of hot pipework and piping loads must be accommodated so that excessive forces are not transmitted to the pump flanges.

When aligning the coupling and checking the connections, the differences between cold installation and hot operating conditions must be taken into account. Sufficient maintenance space must be left for access to the bearings, seal and rotating assembly.

14

Operating limits

The permissible pressure and temperature depend on the pump material, the connection arrangement and the seal selected. The maximum flow, head, speed and temperature values of the series do not describe a single operating point that applies to all models at the same time.

When assessing the pressure acting on the casing, the suction pressure and the pressure rise generated by the pump must be considered together. The closed-valve condition is also part of this assessment.

Final selection should be based on the performance curves, pressure-temperature limits, liquid properties and installation conditions considered together.

Pump designationExample: ECO GCP-HT 100-250
ECO GCP–HT100–250–XXX
ECO GCP
Pump type
HT
High temperature
100
Discharge flange diameter (DN-mm)
250
Nominal impeller diameter (mm)
XXX
Special application
Technical summary

Operating ranges and selection charts

The envelopes show the design range of the series. For a specific duty point the hydraulics are verified by CFD analysis and delivered with the curve sheet, dimensions and, where required, a test report.

25 / 40 barcasing pressure · depends on material, temperature and application
DN 32 – 250discharge flange
1450 / 2900rpm · 50 Hz
1500 m³/hmax. flow · heads up to 160 m

The permissible casing pressure depends on the operating temperature and the material selected. The +230 °C temperature limit and the 40 bar pressure value do not apply at the same time. Final selection must be based on the relevant pressure-temperature limits and the connection arrangement.

General selection chartECO Hot Water and Geothermal Pumps, n = 1450 rpmQ [m³/h] – H [m]Swipe sideways for a closer look
250-500 250-400 250-315 200-500 200-400 200-315 200-260 150-500 150-400 150-315 150-250 150-200 125-400 125-315 125-250 125-200 100-400 100-315 100-250 100-200 100-160 80-400 80-315 80-250 80-200 80-160 65-315 65-250 65-200 65-160 65-125 50-315 50-250 50-200 50-160 50-125 40-250 40-200 40-160 40-125 32-250 32-200 32-160 32-125 5 10 20 30 50 100 200 300 500 1000 2000 2 3 5 10 20 30 50 100 200 300 500 Q [m³/h]l/s US.gpm 30 50 100 200 300 500 1000 2000 3000 5000 IM.gpm 30 50 100 200 300 500 1000 2000 3000 5000 1 2 3 4 5 6 8 10 15 20 30 40 50 60 80 100 120 H [m] 4 5 10 20 30 50 100 150 200 300 ft
General selection chartECO Hot Water and Geothermal Pumps, n = 2900 rpmQ [m³/h] – H [m]Swipe sideways for a closer look
100-315 100-250 100-200 100-160 80-315 80-250 80-200 80-160 65-315 65-250 65-200 65-160 65-125 50-315 50-250 50-200 50-160 50-125 40-250 40-200 40-160 40-125 32-250 32-200 32-160 32-125 5 10 20 30 40 50 100 150 200 300 400 500 600 2 3 4 5 10 20 30 50 100 Q [m³/h]l/s US.gpm 30 40 50 100 200 300 400 500 1000 2000 IM.gpm 30 40 50 100 200 300 400 500 1000 2000 8 10 20 30 40 50 60 70 80 90 100 120 140 160 180 H [m] 30 40 50 100 150 200 300 400 500 ft
MaterialsMaterial options and equivalents
Material options

StandardOptional—Not specified

Swipe sideways to see the full table
MaterialMaterial no.Volute casingSeal chamberImpellerShaftBearing housingWear ringShaft wear sleeve
Cast materials
Grey cast iron0.6025————
Ductile cast iron0.7040——
Cast steel1.0619———
Cr-Ni stainless cast steel1.4308——
Cr-Ni stainless cast steel · low carbon1.4309——
Cr-Ni-Mo stainless cast steel1.4408——
Cr-Ni-Mo stainless cast steel · low carbon1.4409——
Austenitic cast steel1.4500———
Duplex stainless cast steel1.4517———
Super duplex stainless cast steel1.4469———
Martensitic stainless cast steel1.4317———
Martensitic stainless cast steel1.4008———
Steel materials and heat treatment options
Martensitic stainless steel1.4021—————
Martensitic stainless steel · quenched and tempered1.4021 + QT—————
Cr-Ni stainless steel1.4301—————
Cr-Ni-Mo stainless steel · low carbon1.4404—————
Duplex stainless steel1.4460——————
Duplex stainless steel1.4462—————

Suitable for mechanical seals of different types and makes.
Cr: Chromium · Ni: Nickel · Mo: Molybdenum · QT: Quenched and tempered.

Material equivalents
Swipe sideways to see the full table
Material descriptionMaterial no.EN / DIN designationAISI / SAE / ASTM equivalent*
Grey cast iron0.6025EN-GJL-250 (GG25)A48 Class 40B
Ductile cast iron0.7040EN-GJS-400-15 (GGG40)A536 60-40-18
Cast steel1.0619GP240GH (GS-C25)A216 WCB
Cr-Ni stainless cast steel1.4308GX5CrNi19-10A351 CF8
Cr-Ni stainless cast steel · low carbon1.4309GX2CrNi19-11A351 CF3
Cr-Ni-Mo stainless cast steel1.4408GX5CrNiMo19-11-2A351 CF8M
Cr-Ni-Mo stainless cast steel · low carbon1.4409GX2CrNiMo19-11-2A351 CF3M
Austenitic cast steel1.4500GX7NiCrMoCuNb25-20A351 CN7M
Duplex stainless cast steel1.4517GX2CrNiMoCuN25-6-3-3A890 CD4MCuN
Super duplex stainless cast steel1.4469GX2CrNiMoN26-7-4A890 CE3MN
Martensitic stainless cast steel1.4317GX4CrNi13-4A352 CA6NM
Martensitic stainless cast steel1.4008GX7CrNiMo12-1A217 CA15
Martensitic stainless steel1.4021X20Cr13A276 Type 420
Martensitic stainless steel · quenched and tempered1.4021 + QTX20Cr13 + QTA276 Type 420 + QT
Cr-Ni stainless steel1.4301X5CrNi18-10A276 Type 304
Cr-Ni-Mo stainless steel · low carbon1.4404X2CrNiMo17-12-2A276 Type 316L
Duplex stainless steel1.4460X3CrNiMoN27-5-2AISI 329
Duplex stainless steel1.4462X2CrNiMoN22-5-3UNS S32205

* Equivalents are for reference only; materials to different standards may not be identical in every chemical, mechanical and heat treatment requirement. The relevant product standard and material certificate govern the final selection.

For manufacturers

ECO Hot Water and Geothermal Pumps design package

A production-ready series. The package covers hydraulic design, pattern drawings and test verification, giving a manufacturer the design basis to produce the series under its own brand.

WHAT THE PACKAGE INCLUDES

01Hydraulic design

3D impeller and volute models, curve sheets for the models of the series. Parametric 3D models built in Siemens NX and SolidWorks.

02Mechanical design

Dimension drawings, assembly and sectional drawings, parts list. Stress, vibration and fatigue assessments of shaft, impeller and casing components.

03Materials and standards

Material options and equivalents, flange dimensions. EN 1092-2 / PN 25 and PN 40 flanges, ISO 21940-11 G 6.3 impeller balancing.

04Verification

Comparison of design and test results using ANSYS CFX / Fluent-based CFD analyses; test and verification reports depending on project scope.

05Scope of delivery

Manufacturing drawings, casting pattern and core data, manufacturing documentation. Work is carried out on a project basis or under an ongoing outsourced R&D model.

For your company, outsourced R&D

With more than 25 years of pump and turbomachinery experience, we take on your company’s R&D and new product development projects. We complement your production capacity with engineering support that extends from design to production.