Sump Pumps
Vertical, single-stage, end suction centrifugal pumps designed for transferring clean or slightly contaminated process liquids from tanks, vessels and collection pits. The hydraulic section, consisting of a volute casing and closed impeller, sits in the liquid, while the drive motor is located above, outside the liquid.
Column lengths of up to 4 metres allow the pump to be arranged for different pit depths. The discharge pipe extends up to the baseplate to simplify the connection to the pipework.
In this sealless design, the upper rolling bearings are grease-lubricated and the plain bearings in the lower part of the pump are lubricated by the pumped liquid. The liquid properties and the operating liquid level are assessed together when selecting the pump and its bearing arrangement.
Suitable for the transfer of clean or slightly contaminated, low- or medium-viscosity process liquids containing no solid particles or fibres.
The chemical properties of the liquid must be compatible with the materials of the wetted parts and the plain bearings of the pump. Viscosity, temperature and the lubricating properties of the liquid are assessed together when selecting the pump.
With medium-viscosity liquids, flow, head, efficiency and power requirement may differ from those for water, so selection must be based on the properties of the liquid concerned.
Can be adapted to different layouts by selecting the column length to suit the pit depth and operating levels.
No mechanical seal or soft packing is used to seal the pump shaft.
The lower plain bearings are lubricated by the pumped liquid and the upper rolling bearings by grease.
Which industries is it used in?
ECO Norm Sump Pumps are used in many industries to transfer liquids from tanks and vessels. Suitability is determined by taking into account the solids and fibre content, chemical properties, viscosity and temperature of the liquid.
Used in the cooling, service and process water circuits of production plants. For liquids containing solid particles or mill scale, pump type and materials are assessed separately.
Used in auxiliary circuits of power generation plants such as cooling water, drainage and turbine-generator lubricating oil. Pump selection is based on the liquid, temperature and pressure conditions of the circuit concerned.
Used in the auxiliary circuits of food and beverage plants that are not in direct contact with the product. Applications requiring hygienic product transfer are assessed separately.
Used in the process and auxiliary liquid circuits of paper mills. For liquids containing fibres, the pump type is assessed separately according to fibre structure and concentration.
Used in the process and auxiliary liquid circuits of chemical plants. The compatibility of casing, impeller and plain bearing materials with the liquid is assessed for each application.
Used in the water supply, cooling and process circuits of mining facilities. For sludge and slurries containing abrasive solids, pump type and materials are assessed separately.
Used in the cooling, service, process and auxiliary liquid circuits of petroleum facilities. Hydrocarbon transfer and applications requiring special standards or explosive-atmosphere compliance are assessed separately.
Rotate the pump by dragging or with the arrow keys; examine it from every angle.

Vertical column design
The hydraulic section sits in the pit, while the motor and upper bearing arrangement are on the baseplate. The column provides the mechanical connection between the upper support section and the pump casing.
Column lengths of up to 4 metres can be selected. When choosing the length, the pit depth, the minimum and maximum liquid levels, the pump layout and the lifting space needed for maintenance must be taken into account.
Hydraulic design
The single-stage volute casing and closed impeller are suitable for transferring process liquids free of solid particles and fibres. Balancing holes in the impeller help to reduce the axial forces generated during operation.
The pump is selected on the basis of the required flow and head, together with the viscosity, density and temperature of the liquid and the suction conditions.
Discharge pipe and pipework connection
The discharge pipe runs from the pump casing up to the baseplate, carrying the liquid to the pipework connection at the upper level. This arrangement makes it easier to connect the hydraulic section in the pit to the pipework.
The connection between the discharge pipe and the outlet flange is threaded. The pipework layout and pipe supports must be arranged so that no additional loads are placed on the pump connections.
Bearings and lubrication
As standard, grease-lubricated rolling bearings are used in the upper section. The plain bearings in the lower part of the pump are lubricated by the pumped liquid.
For this reason, whether the bearings run under suitable conditions depends on the cleanliness and lubricating properties of the liquid and on the operating liquid level. The plain bearings must not be allowed to run dry; the operating level must be determined from the installation and operating conditions of the pump concerned.
Sealless design
No mechanical seal or soft packing is used to seal the pump shaft, so there is no shaft seal to adjust or replace in this design.
This feature does not mean that the tank is sealed against gas or vapour. For processes in which gas or vapour must be contained, the suitability of the tank and pump connection must be assessed separately.
Material and liquid compatibility
The materials of the wetted casing, impeller, shaft, column, discharge pipe and bearings must be selected to suit the chemical properties and temperature of the liquid.
The concentration, density, viscosity and constituents of the liquid are part of the application assessment.
Flange connections and pressure limit
The suction and discharge flanges comply with EN 1092-2 / PN 16 connection dimensions. The maximum pump casing pressure is 10 bar.
The use of PN 16 flanges does not mean that the pump can operate at a casing pressure of 16 bar. Selection must be based on the casing pressure limit and the operating conditions of the application.
Impeller balancing and direction of rotation
Impellers are balanced statically or dynamically in accordance with ISO 21940-11 balance quality grade G 6.3.
The direction of rotation is clockwise when viewed from the motor end.
Installation and maintenance access
The baseplate and supporting structure must be designed to carry the weight of the pump unit and the operating loads. The arrangement in the pit must allow the liquid to reach the suction area properly.
Sufficient lifting space for the column length and dismantling method must be left so that the unit can be removed for inspection and maintenance. Pipe connections and surrounding equipment must not obstruct this access.
Head and operating limits
The head given in the catalogue refers to the volute casing outlet. When determining the pressure available at the outlet connection at baseplate level, the height difference and hydraulic losses of the vertical discharge pipe must be assessed separately.
The maximum flow, head, column length, speed and temperature values of the series do not describe a single operating point that applies to all models at the same time.
Final selection should be based on the performance curves, column length, liquid levels, liquid properties and pipework requirements considered together.
- ECO GNP
- Pump type
- V
- Vertical sump mounting
- 100
- Discharge flange diameter (DN-mm)
- 250
- Nominal impeller diameter (mm)
- XXX
- Special application
Operating ranges and model range
The envelopes show the design range of the series. For a specific duty point the hydraulics are verified by CFD analysis and delivered with the curve sheet, dimensions and, where required, a test report.
The head is given with reference to the volute casing outlet; see “Head and operating limits” for the effect of the vertical discharge pipe.
1450 rpm
StandardOptional—Not specified
| Material | Material no. | Volute casing | Seal chamber | Impeller | Shaft | Bearing housing | Column pipe | Plain bearing |
|---|---|---|---|---|---|---|---|---|
| Cast materials | ||||||||
| Grey cast iron | 0.6025 | — | — | — | ||||
| Ductile cast iron | 0.7040 | — | — | — | ||||
| Cast steel | 1.0619 | — | — | — | — | |||
| Cr-Ni stainless cast steel | 1.4308 | — | — | — | ||||
| Cr-Ni stainless cast steel · low carbon | 1.4309 | — | — | — | ||||
| Cr-Ni-Mo stainless cast steel | 1.4408 | — | — | — | ||||
| Cr-Ni-Mo stainless cast steel · low carbon | 1.4409 | — | — | — | ||||
| Austenitic cast steel | 1.4500 | — | — | — | — | |||
| Duplex stainless cast steel | 1.4517 | — | — | — | — | |||
| Super duplex stainless cast steel | 1.4469 | — | — | — | — | |||
| Martensitic stainless cast steel | 1.4317 | — | — | — | — | |||
| Martensitic stainless cast steel | 1.4008 | — | — | — | — | |||
| Tin bronze | 2.1050.01 | — | — | — | ||||
| Nickel-aluminium bronze | 2.0975.01 | — | — | — | — | — | — | |
| Leaded bronze | 2.1096.01 | — | — | — | — | — | — | |
| Steel materials and heat treatment options | ||||||||
| Structural steel | 1.0037 | — | — | — | — | — | — | |
| Carbon steel | 1.0503 | — | — | — | — | — | — | |
| Martensitic stainless steel | 1.4021 | — | — | — | — | — | — | |
| Martensitic stainless steel · quenched and tempered | 1.4021 + QT | — | — | — | — | — | — | |
| Cr-Ni stainless steel | 1.4301 | — | — | — | — | — | ||
| Cr-Ni-Mo stainless steel · low carbon | 1.4404 | — | — | — | — | — | ||
| Duplex stainless steel | 1.4460 | — | — | — | — | — | — | |
| Duplex stainless steel | 1.4462 | — | — | — | — | — | — | |
| Polymer and carbon materials | ||||||||
| Polytetrafluoroethylene | PTFE | — | — | — | — | — | — | |
| Carbon | — | — | — | — | — | — | — | |
No shaft seal is used on this pump.
Cr: Chromium · Ni: Nickel · Mo: Molybdenum · QT: Quenched and tempered.
| Material description | Material no. | EN / DIN designation | AISI / SAE / ASTM equivalent* |
|---|---|---|---|
| Grey cast iron | 0.6025 | EN-GJL-250 (GG25) | A48 Class 40B |
| Ductile cast iron | 0.7040 | EN-GJS-400-15 (GGG40) | A536 60-40-18 |
| Ductile cast iron · low temperature | 0.7043 | EN-GJS-400-18-LT (GGG40.3) | A536 60-40-18 |
| Cast steel | 1.0619 | GP240GH (GS-C25) | A216 WCB |
| Cr-Ni stainless cast steel | 1.4308 | GX5CrNi19-10 | A351 CF8 |
| Cr-Ni stainless cast steel · low carbon | 1.4309 | GX2CrNi19-11 | A351 CF3 |
| Cr-Ni-Mo stainless cast steel | 1.4408 | GX5CrNiMo19-11-2 | A351 CF8M |
| Cr-Ni-Mo stainless cast steel · low carbon | 1.4409 | GX2CrNiMo19-11-2 | A351 CF3M |
| Austenitic cast steel | 1.4500 | GX7NiCrMoCuNb25-20 | A351 CN7M |
| Duplex stainless cast steel | 1.4517 | GX2CrNiMoCuN25-6-3-3 | A890 CD4MCuN |
| Super duplex stainless cast steel | 1.4469 | GX2CrNiMoN26-7-4 | A890 CE3MN |
| Martensitic stainless cast steel | 1.4317 | GX4CrNi13-4 | A352 CA6NM |
| Martensitic stainless cast steel | 1.4008 | GX7CrNiMo12-1 | A217 CA15 |
| Tin bronze | 2.1050.01 | G-CuSn10 | B427 C90700 |
| Nickel-aluminium bronze | 2.0975.01 | G-CuAl10Ni | B148 C95500 |
| Leaded bronze | 2.1096.01 | G-CuSn5ZnPb | B584 C83600 |
| Structural steel | 1.0037 | St37 | A29 1015 |
| Carbon steel | 1.0503 | C45 | AISI 1045 |
| Martensitic stainless steel | 1.4021 | X20Cr13 | A276 Type 420 |
| Martensitic stainless steel · quenched and tempered | 1.4021 + QT | X20Cr13 + QT | A276 Type 420 + QT |
| Cr-Ni stainless steel | 1.4301 | X5CrNi18-10 | A276 Type 304 |
| Cr-Ni-Mo stainless steel · low carbon | 1.4404 | X2CrNiMo17-12-2 | A276 Type 316L |
| Duplex stainless steel | 1.4460 | X3CrNiMoN27-5-2 | AISI 329 |
| Duplex stainless steel | 1.4462 | X2CrNiMoN22-5-3 | UNS S32205 |
* Equivalents are for reference only; materials to different standards may not be identical in every chemical, mechanical and heat treatment requirement. The relevant product standard and material certificate govern the final selection.
ECO Sump Pumps design package
A production-ready series of 40 models. The package covers hydraulic design, pattern drawings and test verification, giving a manufacturer the design basis to produce the series under its own brand.
WHAT THE PACKAGE INCLUDES
3D impeller and volute models, curve sheets for 40 models. Parametric 3D models built in Siemens NX and SolidWorks.
Dimension drawings, assembly and sectional drawings, parts list. Stress, vibration and fatigue assessments of shaft, impeller and casing components.
Material options and equivalents, flange dimensions. EN 1092-2 / PN 16 flanges, ISO 21940-11 G 6.3 impeller balancing.
Comparison of design and test results using ANSYS CFX / Fluent-based CFD analyses; test and verification reports depending on project scope.
Manufacturing drawings, casting pattern and core data, manufacturing documentation. Work is carried out on a project basis or under an ongoing outsourced R&D model.
ECO Types 10
ECO EN 733 Norm Centrifugal Pumps02
ECO EN 733 Norm Centrifugal Pumps - Vertical03THIS PAGE
ECO Sump Pumps04
ECO EN 733 Close-Coupled Pumps05
ECO EN 733 Close-Coupled Pumps - Vertical06
ECO In-Line Centrifugal Pumps07
ECO In-Line Centrifugal Pumps - With Separate Bearing Bracket08
ECO Thermal Oil Pumps09
ECO EN ISO 2858 Chemical Process Pumps10
ECO Hot Water and Geothermal Pumps