The GSP series consists of vertical-shaft, single-stage submersible centrifugal pumps with volute casing, used to transfer domestic and industrial waste water and liquids containing solids or fibrous matter of suitable size and nature.
The pump and the submersible electric motor form a single unit. The liquid reaches the impeller through the bottom suction section and is delivered from the volute casing to the discharge line with the energy imparted by the impeller.
Closed, semi-open and vortex impeller options are evaluated according to the content of the waste water and the required duty point. Impeller selection is not based on flow and head alone; solid particle size, fibre content, abrasiveness and clogging tendency are also taken into account.
The submersible design allows use in waste water collection sumps and lifting stations. The minimum operating level, the motor cooling conditions and the installation arrangement are determined by the selected model.
The GSP series is used to transfer raw domestic sewage, industrial waste water of suitable nature and liquids containing solids or fibrous matter within the passage capacity of the model.
The size and nature of solid particles, fibre length, sand content, abrasiveness and chemical composition should be evaluated in pump selection.
Not every impeller type is equally suitable for every waste water content. Applications with a high sand load, dense sludge, hard foreign objects or aggressive chemicals should be examined separately.
Closed, semi-open and vortex impeller designs are selected according to the waste water content and the duty point. Solids passage is determined by the hydraulic design of the respective model.
The pump and motor form a single unit. Liquid level and motor cooling are evaluated together so that the pump can operate continuously and correctly.
A mechanical seal arrangement and oil chamber suited to the model provide the sealing; protection sensors monitor the seal and motor condition. A suitable control panel completes the protection functions.
Which industries is it used in?
Submersible sewage pumps are used for collecting, lifting and draining domestic and industrial waste water. Suitability for an application is determined by the solids and fibre content, abrasiveness, temperature and chemical composition.
Transfer of domestic and industrial waste water, treatment plant duties and conveying of sludge-laden liquids with suitable properties.
Central waste water collection and transfer systems of large buildings and campuses.
Contaminated process water and industrial waste water lines containing solid particles.
Transfer of plant waste water, dirty drainage and suitable process liquids.
Waste water from production and process waste containing organic particles.
Dirty water and process waste water applications whose solids content and abrasiveness have been evaluated.
Transfer of plant waste water and dirty process water, with materials and sealing selected to suit the liquid properties.
Rotate the pump by dragging or with the arrow keys; examine it from every angle.


Single-stage submersible design
The pump consists of a single hydraulic stage and the submersible electric motor connected to it. Motor power is transmitted to the impeller through a common shaft system.
In a submersible design, the motor must be built for operation in the liquid. However, the permissible submergence depth, operating time and minimum liquid level depend on the technical data of the respective model.
Whether the pump can operate out of the liquid or partly submerged can only be determined by the cooling and operating arrangement of the selected model.
Closed impeller options
Wide-channel closed impellers are hydraulic designs that allow solids of suitable size to pass.
The number of channels, impeller geometry and speed affect flow, head, efficiency and solids passage. A high-flow closed impeller and another closed impeller designed for higher head may not have the same passage characteristics.
Selection should be based on the performance and solids passage data of the respective model.
Semi-open impeller options
In semi-open impellers, the running clearance between the impeller and the opposing surface affects hydraulic performance.
In models with a wear plate or adjustable clearance, changes caused by wear are checked during maintenance. Clearance should be adjusted in accordance with the operating instructions of the respective model.
Having a semi-open impeller does not mean that the pump can pass solids of any size.
Vortex impeller option
A vortex impeller transfers energy by creating a rotating motion in the liquid inside the volute. In suitable models, the free-flow design can be considered for fibrous matter and liquids containing solids.
The position of the impeller in the flow path and the casing geometry determine the passage characteristics. The efficiency and head characteristics of a vortex design may differ from those of channel impellers.
Not every vortex model offers a solids passage equal to the discharge flange diameter.
Solids passage and clogging behaviour
The DN size of the discharge flange and the free solids passage of the pump are not the same information. Solids passage is determined by the flow path through the impeller and casing.
The fact that a round solid can pass does not mean that long fibres, rags or rope-like material will pass as easily.
In pump selection, fibre structure, foreign object content and operating flow should be evaluated in addition to particle size. No impeller type is non-clogging under all conditions.
Evaluating cutter arrangements
Special arrangements with a cutter blade aim to reduce the size of suitable soft solids and deliver them to the discharge line.
This feature is not available on all submersible sewage pumps or on all semi-open impellers. Cutter availability is confirmed for each GURDE model.
The cutter is not designed to cut hard metal, stone or similar foreign objects.
Motor protection class and cooling
The reference motor design has IP68 protection. The permissible submergence conditions are given in the technical documentation of each model.
Motor cooling is evaluated together with the operating level of the pump in the liquid and any special cooling system. IP68 does not mean dry running or unlimited submergence depth.
An additional motor cooling system can be considered for suitable models. The availability of such an option does not mean that all models are suitable for dry installation or continuous operation out of the liquid.
Shaft sealing and oil chamber
Shaft sealing is provided by a single or double mechanical seal arrangement, depending on the power and design of the model.
In double mechanical seal arrangements, the sealing elements on the product side and the motor side work together. In this design, the oil chamber forms part of the seal operating environment and of leakage monitoring.
Seal faces, elastomers and oil properties should be selected to suit the liquid, temperature and operating conditions.
Bearings and axial loads
The reference design uses sealed bearings that are grease-lubricated for life. These bearings still have a finite life, and the pump needs regular maintenance.
In this design, back vanes on the impeller help reduce axial load and the pressure at the seal area.
Bearing condition, vibration, noise and, where available, temperature monitoring data should be evaluated during maintenance.
Motor and leakage monitoring
In suitably equipped models, winding temperature and leakage sensors are used to monitor the motor and the sealing system.
The sensors provide protection only when correctly connected to a suitable relay and control panel. Phase failure, overload, level control and alarm functions are defined by the panel design.
Sensor type, alarm threshold and restart behaviour can differ between models.
Installation and level control
The installation arrangement is determined by the sump geometry, the discharge line and maintenance needs. Guide rail, automatic coupling foot or portable installation options are offered only for models that support them.
Start and stop levels are set taking into account motor cooling, air entrainment and the permissible starting frequency.
The designated lifting points should be used to lift the pump. The power cable must not be used as a lifting element.
Material and liquid compatibility
The casing, impeller, shaft, wear parts and sealing elements are selected according to the chemical and abrasive properties of the waste water.
Suitability for industrial waste water does not imply resistance to all chemicals or to high abrasiveness. In particular, sand, salt, oil and chemical content should be evaluated separately.
The exact material combination is stated in the technical specification of the selected model.
Temperature and operating limits
The upper liquid temperature limit for the standard series is +40 °C.
Applications requiring higher temperatures can be handled as special designs, evaluating motor cooling, cable, seal, elastomer and bearing conditions together. For higher temperatures, the permissible value is set from the verified data of the model concerned.
The thermal protection temperature of the motor winding is not the permissible temperature of the pumped liquid.
Pump selection and maintenance
In addition to flow and head, selection takes into account solids passage, fibre content, impeller type, motor power, liquid level, cooling, materials and sealing arrangement.
Whether the pump runs within its intended operating range directly affects motor load, vibration, clogging tendency and energy consumption.
During maintenance, impeller and casing wear, running clearances, seals, the oil chamber, cable entries and protective equipment are checked in accordance with the respective operating instructions.
Technical data and operating ranges
The envelopes show the design range of the series at 960, 1450 and 2900 rpm, grouped by discharge flange size. For a specific duty point the hydraulics are verified by CFD analysis and delivered with the curve sheet, dimensions and, where required, a test report.
The values given are the general operating limits of the series. Maximum flow, head and speed values do not apply together at the same operating point. Pump, impeller, motor, sealing and cooling arrangement are selected according to the liquid properties and operating conditions.
DN 40DN 50DN 65DN 80DN 100DN 150DN 200DN 250DN 300DN 350DN 400Solid line: 1450 / 960 rpmDashed line: 2900 rpm
The envelopes are coloured by discharge flange (DN) group. The discharge flange size does not indicate the free solids passage of the pump.
StandardOptional—Not specified
| Material | Material no. | Volute casing | Motor housing | Impeller | Rotor shaft | Oil chamber |
|---|---|---|---|---|---|---|
| Cast materials | ||||||
| Grey cast iron | 0.6025 | — | ||||
| Ductile cast iron | 0.7040 | — | ||||
| Cast steel | 1.0619 | — | — | — | ||
| Cr-Ni stainless cast steel | 1.4308 | — | — | |||
| Cr-Ni stainless cast steel · low carbon | 1.4309 | — | — | — | ||
| Cr-Ni-Mo stainless cast steel | 1.4408 | — | — | |||
| Cr-Ni-Mo stainless cast steel · low carbon | 1.4409 | — | — | — | ||
| Duplex stainless cast steel | 1.4517 | — | — | — | ||
| Martensitic stainless cast steel | 1.4317 | — | — | — | ||
| Tin bronze | 2.1050.01 | — | — | — | ||
| Nickel-aluminium bronze | 2.0975.01 | — | — | — | — | |
| Steel materials | ||||||
| Martensitic stainless steel | 1.4021 | — | — | — | — | |
The exact material combination is stated in the technical specification of the selected model.
Cr: Chromium · Ni: Nickel · Mo: Molybdenum.
| Material description | Material no. | EN / DIN designation | AISI / SAE / ASTM equivalent* |
|---|---|---|---|
| Grey cast iron | 0.6025 | EN-GJL-250 (GG25) | A48 Class 40B |
| Ductile cast iron | 0.7040 | EN-GJS-400-15 (GGG40) | A536 60-40-18 |
| Cast steel | 1.0619 | GP240GH (GS-C25) | A216 WCB |
| Cr-Ni stainless cast steel | 1.4308 | GX5CrNi19-10 | A351/743/744 CF8 |
| Cr-Ni stainless cast steel · low carbon | 1.4309 | GX2CrNi19-11 | A351/743/744 CF3 |
| Cr-Ni-Mo stainless cast steel | 1.4408 | GX5CrNiMo19-11-2 | A351/743/744 CF8M |
| Cr-Ni-Mo stainless cast steel · low carbon | 1.4409 | GX2CrNiMo19-11-2 | A351/743/744 CF3M |
| Duplex stainless cast steel | 1.4517 | GX2CrNiMoCuN25-6-3-3 | A890 Gr. 1B (CD4MCuN) |
| Martensitic stainless cast steel | 1.4317 | GX4CrNi13-4 | A351/743/744 CA6NM |
| Tin bronze | 2.1050.01 | G-CuSn10 | B584 C90700 |
| Nickel-aluminium bronze | 2.0975.01 | G-CuAl10Ni | B148 C95800 |
| Martensitic stainless steel | 1.4021 | X20Cr13 | A276 Type 420 |
* Equivalents are for reference only; materials to different standards may not be identical in every chemical, mechanical and heat treatment requirement. The relevant product standard and material certificate govern the final selection.
Submersible Sewage Pump design package
A submersible sewage pump series with closed, semi-open and vortex impeller options. From hydraulic design to pattern drawings and test verification: the design foundation a manufacturer needs to produce under its own brand.
WHAT THE PACKAGE INCLUDES
3D impeller and volute models, curve sheets for the models of the series. Parametric 3D models built in Siemens NX and SolidWorks.
Dimension drawings, assembly and sectional drawings, parts list. Stress, vibration and fatigue assessments of shaft, impeller and casing components.
Material options and equivalents, flange dimensions. Discharge flanges to EN 1092-2 / PN 10 (PN 6 for DN 80 and DN 100); ISO 21940-11 G 6.3 impeller balancing.
Comparison of design and test results using ANSYS CFX / Fluent-based CFD analyses; test and verification reports depending on project scope.
Manufacturing drawings, casting pattern and core data, manufacturing documentation. Work is carried out on a project basis or under an ongoing outsourced R&D model.