GURDE Submersible Sewage Pumps (GSP)
GSP · SUBMERSIBLE

Submersible SewagePumps

DN40 – DN400Discharge flange
up to 4480 m³/hCapacity
up to 100 mHead
up to 2900 rpmSpeed
up to +40 °COperating temperature
10 barCasing pressure (Pmax)
Product Description

Submersible Sewage Pumps

The GSP series consists of vertical-shaft, single-stage submersible centrifugal pumps with volute casing, used to transfer domestic and industrial waste water and liquids containing solids or fibrous matter of suitable size and nature.

The pump and the submersible electric motor form a single unit. The liquid reaches the impeller through the bottom suction section and is delivered from the volute casing to the discharge line with the energy imparted by the impeller.

Closed, semi-open and vortex impeller options are evaluated according to the content of the waste water and the required duty point. Impeller selection is not based on flow and head alone; solid particle size, fibre content, abrasiveness and clogging tendency are also taken into account.

The submersible design allows use in waste water collection sumps and lifting stations. The minimum operating level, the motor cooling conditions and the installation arrangement are determined by the selected model.

Liquids handled

The GSP series is used to transfer raw domestic sewage, industrial waste water of suitable nature and liquids containing solids or fibrous matter within the passage capacity of the model.

The size and nature of solid particles, fibre length, sand content, abrasiveness and chemical composition should be evaluated in pump selection.

Not every impeller type is equally suitable for every waste water content. Applications with a high sand load, dense sludge, hard foreign objects or aggressive chemicals should be examined separately.

Standards and design
Flange connectionsDischarge flanges comply with EN 1092-2 / PN 10; DN 80 and DN 100 discharge flanges are made to PN 6.
ISO 21940-11 G 6.3Impeller balancing grade
Vertical shaft, single-stageSubmersible centrifugal design with volute casing
Closed, semi-open, vortexImpeller options
Submersible motorThe operating level and cooling arrangement are determined by the model.
01Impeller selected for the liquid

Closed, semi-open and vortex impeller designs are selected according to the waste water content and the duty point. Solids passage is determined by the hydraulic design of the respective model.

02Submersible motor design

The pump and motor form a single unit. Liquid level and motor cooling are evaluated together so that the pump can operate continuously and correctly.

03Sealing and monitoring

A mechanical seal arrangement and oil chamber suited to the model provide the sealing; protection sensors monitor the seal and motor condition. A suitable control panel completes the protection functions.

Applications

Which industries is it used in?

7applications

Submersible sewage pumps are used for collecting, lifting and draining domestic and industrial waste water. Suitability for an application is determined by the solids and fibre content, abrasiveness, temperature and chemical composition.

Waste Water01

Transfer of domestic and industrial waste water, treatment plant duties and conveying of sludge-laden liquids with suitable properties.

Building Systems02

Central waste water collection and transfer systems of large buildings and campuses.

Iron and Steel Industry03

Contaminated process water and industrial waste water lines containing solid particles.

Power Plant04

Transfer of plant waste water, dirty drainage and suitable process liquids.

Food & Beverage Industry05

Waste water from production and process waste containing organic particles.

Mining06

Dirty water and process waste water applications whose solids content and abrasiveness have been evaluated.

Petroleum Industry07

Transfer of plant waste water and dirty process water, with materials and sealing selected to suit the liquid properties.

360° view

Rotate the pump by dragging or with the arrow keys; examine it from every angle.

Small submersibles (up to 12 HP)GURDE Submersible Sewage Pump
Large submersibles (above 12 HP)GURDE Submersible Sewage Pump
Technical notes
01

Single-stage submersible design

The pump consists of a single hydraulic stage and the submersible electric motor connected to it. Motor power is transmitted to the impeller through a common shaft system.

In a submersible design, the motor must be built for operation in the liquid. However, the permissible submergence depth, operating time and minimum liquid level depend on the technical data of the respective model.

Whether the pump can operate out of the liquid or partly submerged can only be determined by the cooling and operating arrangement of the selected model.

02

Closed impeller options

Wide-channel closed impellers are hydraulic designs that allow solids of suitable size to pass.

The number of channels, impeller geometry and speed affect flow, head, efficiency and solids passage. A high-flow closed impeller and another closed impeller designed for higher head may not have the same passage characteristics.

Selection should be based on the performance and solids passage data of the respective model.

03

Semi-open impeller options

In semi-open impellers, the running clearance between the impeller and the opposing surface affects hydraulic performance.

In models with a wear plate or adjustable clearance, changes caused by wear are checked during maintenance. Clearance should be adjusted in accordance with the operating instructions of the respective model.

Having a semi-open impeller does not mean that the pump can pass solids of any size.

04

Vortex impeller option

A vortex impeller transfers energy by creating a rotating motion in the liquid inside the volute. In suitable models, the free-flow design can be considered for fibrous matter and liquids containing solids.

The position of the impeller in the flow path and the casing geometry determine the passage characteristics. The efficiency and head characteristics of a vortex design may differ from those of channel impellers.

Not every vortex model offers a solids passage equal to the discharge flange diameter.

05

Solids passage and clogging behaviour

The DN size of the discharge flange and the free solids passage of the pump are not the same information. Solids passage is determined by the flow path through the impeller and casing.

The fact that a round solid can pass does not mean that long fibres, rags or rope-like material will pass as easily.

In pump selection, fibre structure, foreign object content and operating flow should be evaluated in addition to particle size. No impeller type is non-clogging under all conditions.

06

Evaluating cutter arrangements

Special arrangements with a cutter blade aim to reduce the size of suitable soft solids and deliver them to the discharge line.

This feature is not available on all submersible sewage pumps or on all semi-open impellers. Cutter availability is confirmed for each GURDE model.

The cutter is not designed to cut hard metal, stone or similar foreign objects.

07

Motor protection class and cooling

The reference motor design has IP68 protection. The permissible submergence conditions are given in the technical documentation of each model.

Motor cooling is evaluated together with the operating level of the pump in the liquid and any special cooling system. IP68 does not mean dry running or unlimited submergence depth.

An additional motor cooling system can be considered for suitable models. The availability of such an option does not mean that all models are suitable for dry installation or continuous operation out of the liquid.

08

Shaft sealing and oil chamber

Shaft sealing is provided by a single or double mechanical seal arrangement, depending on the power and design of the model.

In double mechanical seal arrangements, the sealing elements on the product side and the motor side work together. In this design, the oil chamber forms part of the seal operating environment and of leakage monitoring.

Seal faces, elastomers and oil properties should be selected to suit the liquid, temperature and operating conditions.

09

Bearings and axial loads

The reference design uses sealed bearings that are grease-lubricated for life. These bearings still have a finite life, and the pump needs regular maintenance.

In this design, back vanes on the impeller help reduce axial load and the pressure at the seal area.

Bearing condition, vibration, noise and, where available, temperature monitoring data should be evaluated during maintenance.

10

Motor and leakage monitoring

In suitably equipped models, winding temperature and leakage sensors are used to monitor the motor and the sealing system.

The sensors provide protection only when correctly connected to a suitable relay and control panel. Phase failure, overload, level control and alarm functions are defined by the panel design.

Sensor type, alarm threshold and restart behaviour can differ between models.

11

Installation and level control

The installation arrangement is determined by the sump geometry, the discharge line and maintenance needs. Guide rail, automatic coupling foot or portable installation options are offered only for models that support them.

Start and stop levels are set taking into account motor cooling, air entrainment and the permissible starting frequency.

The designated lifting points should be used to lift the pump. The power cable must not be used as a lifting element.

12

Material and liquid compatibility

The casing, impeller, shaft, wear parts and sealing elements are selected according to the chemical and abrasive properties of the waste water.

Suitability for industrial waste water does not imply resistance to all chemicals or to high abrasiveness. In particular, sand, salt, oil and chemical content should be evaluated separately.

The exact material combination is stated in the technical specification of the selected model.

13

Temperature and operating limits

The upper liquid temperature limit for the standard series is +40 °C.

Applications requiring higher temperatures can be handled as special designs, evaluating motor cooling, cable, seal, elastomer and bearing conditions together. For higher temperatures, the permissible value is set from the verified data of the model concerned.

The thermal protection temperature of the motor winding is not the permissible temperature of the pumped liquid.

14

Pump selection and maintenance

In addition to flow and head, selection takes into account solids passage, fibre content, impeller type, motor power, liquid level, cooling, materials and sealing arrangement.

Whether the pump runs within its intended operating range directly affects motor load, vibration, clogging tendency and energy consumption.

During maintenance, impeller and casing wear, running clearances, seals, the oil chamber, cable entries and protective equipment are checked in accordance with the respective operating instructions.

Technical summary

Technical data and operating ranges

The envelopes show the design range of the series at 960, 1450 and 2900 rpm, grouped by discharge flange size. For a specific duty point the hydraulics are verified by CFD analysis and delivered with the curve sheet, dimensions and, where required, a test report.

DN 40 – 400discharge flange
960 – 2900rpm · 50 Hz · group chart 960, 1450 and 2900 rpm
4480 m³/hmax. flow · heads up to 100 m
10 barcasing pressure (Pmax) · liquid temperature up to +40 °C

The values given are the general operating limits of the series. Maximum flow, head and speed values do not apply together at the same operating point. Pump, impeller, motor, sealing and cooling arrangement are selected according to the liquid properties and operating conditions.

Group chartSubmersible Sewage Pumps · 50 Hz · 2900 / 1450 / 960 rpmQ [m³/h] – H [m]Swipe sideways for a closer look

DN 40DN 50DN 65DN 80DN 100DN 150DN 200DN 250DN 300DN 350DN 400Solid line: 1450 / 960 rpmDashed line: 2900 rpm

2 3 5 10 20 30 50 100 200 300 500 1000 2000 3000 5000 Q [m³/h]l/s 0.3 0.5 1 2 3 5 10 20 30 50 100 200 300 500 1000 US.gpm 5 10 20 30 50 100 200 300 500 1000 2000 3000 5000 10000 20000 IM.gpm 5 10 20 30 50 100 200 300 500 1000 2000 3000 5000 10000 20000 1 1.5 2 3 4 5 6 8 10 15 20 30 40 50 60 80 100 H [m] 5 10 20 30 50 100 200 300 ft

The envelopes are coloured by discharge flange (DN) group. The discharge flange size does not indicate the free solids passage of the pump.

Model listSubmersible Sewage Pumps · 32 models · by discharge flange
DN 401 model
40-250
DN 504 models
50-16050-20050-24050-270
DN 651 model
65-250
DN 805 models
80-16080-20080-24080-27080-315
DN 1004 models
100-240100-270100-315100-400
DN 1503 models
150-315150-400150-500
DN 2003 models
200-315200-400200-500
DN 2502 models
250-315250-400
DN 3003 models
300-400300-420300-500
DN 3503 models
350-350350-600350-700
DN 4003 models
400-400400-600400-900
MaterialsMaterial options and equivalents
Material options

StandardOptional—Not specified

Swipe sideways to see the full table
MaterialMaterial no.Volute casingMotor housingImpellerRotor shaftOil chamber
Cast materials
Grey cast iron0.6025—
Ductile cast iron0.7040—
Cast steel1.0619———
Cr-Ni stainless cast steel1.4308——
Cr-Ni stainless cast steel · low carbon1.4309———
Cr-Ni-Mo stainless cast steel1.4408——
Cr-Ni-Mo stainless cast steel · low carbon1.4409———
Duplex stainless cast steel1.4517———
Martensitic stainless cast steel1.4317———
Tin bronze2.1050.01———
Nickel-aluminium bronze2.0975.01————
Steel materials
Martensitic stainless steel1.4021————

The exact material combination is stated in the technical specification of the selected model.
Cr: Chromium · Ni: Nickel · Mo: Molybdenum.

Material equivalents
Swipe sideways to see the full table
Material descriptionMaterial no.EN / DIN designationAISI / SAE / ASTM equivalent*
Grey cast iron0.6025EN-GJL-250 (GG25)A48 Class 40B
Ductile cast iron0.7040EN-GJS-400-15 (GGG40)A536 60-40-18
Cast steel1.0619GP240GH (GS-C25)A216 WCB
Cr-Ni stainless cast steel1.4308GX5CrNi19-10A351/743/744 CF8
Cr-Ni stainless cast steel · low carbon1.4309GX2CrNi19-11A351/743/744 CF3
Cr-Ni-Mo stainless cast steel1.4408GX5CrNiMo19-11-2A351/743/744 CF8M
Cr-Ni-Mo stainless cast steel · low carbon1.4409GX2CrNiMo19-11-2A351/743/744 CF3M
Duplex stainless cast steel1.4517GX2CrNiMoCuN25-6-3-3A890 Gr. 1B (CD4MCuN)
Martensitic stainless cast steel1.4317GX4CrNi13-4A351/743/744 CA6NM
Tin bronze2.1050.01G-CuSn10B584 C90700
Nickel-aluminium bronze2.0975.01G-CuAl10NiB148 C95800
Martensitic stainless steel1.4021X20Cr13A276 Type 420

* Equivalents are for reference only; materials to different standards may not be identical in every chemical, mechanical and heat treatment requirement. The relevant product standard and material certificate govern the final selection.

For manufacturers

Submersible Sewage Pump design package

A submersible sewage pump series with closed, semi-open and vortex impeller options. From hydraulic design to pattern drawings and test verification: the design foundation a manufacturer needs to produce under its own brand.

WHAT THE PACKAGE INCLUDES

01Hydraulic design

3D impeller and volute models, curve sheets for the models of the series. Parametric 3D models built in Siemens NX and SolidWorks.

02Mechanical design

Dimension drawings, assembly and sectional drawings, parts list. Stress, vibration and fatigue assessments of shaft, impeller and casing components.

03Materials and standards

Material options and equivalents, flange dimensions. Discharge flanges to EN 1092-2 / PN 10 (PN 6 for DN 80 and DN 100); ISO 21940-11 G 6.3 impeller balancing.

04Verification

Comparison of design and test results using ANSYS CFX / Fluent-based CFD analyses; test and verification reports depending on project scope.

05Scope of delivery

Manufacturing drawings, casting pattern and core data, manufacturing documentation. Work is carried out on a project basis or under an ongoing outsourced R&D model.

For your company, outsourced R&D

With more than 25 years of pump and turbomachinery experience, we take on your company’s R&D and new product development projects. We complement your production capacity with engineering support that extends from design to production.