GURDE Horizontal Multistage Centrifugal Pumps (End Suction) (GMS-E)
GMS-E · HORIZONTAL · END SUCTION

Horizontal Multistage Centrifugal Pumps(End Suction)

DN40 – DN150Discharge flange
up to 400 m³/hCapacity
up to 450 mHead
up to 2900 rpmSpeed
-10 °C to +140 °COperating temperature
30 / 63 barCasing pressure (Pmax)
Product Description

Horizontal Multistage Centrifugal Pumps (End Suction)

Horizontal, end suction, diffuser-type multistage centrifugal pumps for water transfer and pressure boosting applications that require a high head. The axial suction connection and ring-section casing allow the pump to be adapted to the plant layout and the duty point.

The GMS-E series consists of horizontal, end suction, ring-section multistage centrifugal pumps with diffusers and closed impellers, used for transferring clean or very slightly contaminated, low-viscosity liquids at high heads.

The liquid enters through the suction connection at the end of the pump, along the shaft axis. As it passes in turn through the impeller and diffuser stages, its pressure rises step by step, and it is delivered to the system through the discharge casing.

The radially split casing is made up of the suction, stage and discharge casings. A pump suited to the required duty point is selected by assessing the hydraulic size and number of stages together with the mechanical operating limits.

All impellers are of the closed type. The GMS-E series is used in water supply, water transfer to high elevations, industrial pressure boosting, agricultural irrigation and plant service water applications.

Liquids handled

The GMS-E series is used for transferring clean or very slightly contaminated, low-viscosity liquids containing no solid particles or fibres.

Clean water, conditioned plant water, process auxiliary water of suitable quality and hot water are assessed within the material, temperature and pressure limits of the selected pump.

The chemical composition, corrosiveness and lubricating properties of the liquid must be checked for compatibility with the wetted parts, the plain bearing and the sealing elements.

The series is not suitable for waste water containing solids or fibres.

Standards and design
EN 1092-2 / PN16Suction flanges
EN 1092-2 / PN40–PN63Discharge flanges depending on the arrangement selected
ISO 21940-11 G 6.3Impeller balancing grade
01End suction connection

The liquid is taken in at the end of the pump, along the shaft axis. This connection layout suits installations where the suction line runs along the pump axis.

02Multistage pressure boosting

Impeller and diffuser stages working in series raise the pressure of the liquid step by step. The number of stages is determined by the required head and the mechanical limits of the model.

03Bearing arrangement for end suction

A plain bearing on the suction side, lubricated by the pumped liquid, and a rolling bearing arrangement on the drive side support the rotor. Liquid properties and lubrication conditions are taken into account in selection.

Applications

Which industries is it used in?

12applications

The GMS-E series is used in water transfer and pressure boosting applications that require a high head. Suitability is determined by the properties of the liquid and the operating temperature and pressure.

Building Systems01

Used in the water transfer, pressure boosting and mechanical services circuits of commercial and industrial buildings. The pump type is selected according to the liquid in the circuit and the flow and pressure required.

Iron and Steel Industry02

Used in the descaling, cooling and service water circuits of steel plants. The pump handles clean water; for liquids containing solid particles, the pump type is assessed separately.

Marine03

Used in the transfer, cooling and auxiliary service circuits of ships and coastal facilities. Sea water applications require materials and sealing suited to the liquid.

Power Plant04

Used in the cooling, service, feed and auxiliary liquid circuits of power generation plants. Pump selection is based on the liquid, temperature and pressure conditions of the circuit concerned.

Food & Beverage Industry05

Used in the auxiliary circuits of food and beverage plants that are not in direct contact with the product. Applications requiring hygienic product transfer are assessed separately.

Heating & Cooling06

Used in the circulation circuits of central and industrial heating, cooling and air-conditioning systems. The type of liquid, its additives and the operating temperature are taken into account when selecting materials and sealing.

Chemical Industry07

Used in the process and auxiliary liquid circuits of chemical plants. The compatibility of casing, impeller and sealing materials with the liquid is assessed separately for each application.

Mining08

Used in the water supply, cooling and process water circuits of mining facilities. Sludge and slurries containing abrasive solids are outside the scope of this series.

Petroleum Industry09

Used in the cooling, service, process and auxiliary liquid circuits of petroleum facilities. Hydrocarbon transfer and applications requiring special standards or explosive-atmosphere compliance are assessed separately.

Water Supply and Treatment10

Used in the transfer and pressure boosting circuits of water supply, distribution and treatment plants. The pump type is selected according to the quality of the water and its solids and fibre content.

Agricultural Irrigation11

Used for the transfer of irrigation water and to feed pressurised irrigation systems. Pump selection is based on the suction conditions at the water source and the flow and pressure demand of the irrigation system.

Fire Fighting12

For fire water supply applications, models suited to the flow and pressure requirements of the system concerned are evaluated. Operating speed, performance and the required approvals must be verified separately according to the project specification.

360° view

Rotate the pump by dragging or with the arrow keys; examine it from every angle.

GMS-E · End suctionGURDE Horizontal Multistage Centrifugal Pump (End Suction)
Technical features
01

End suction and connection layout

The suction flange is at the end of the pump, along the shaft axis. The discharge connection is radial; in the standard reference layout the discharge flange is on top.

The drive connection is on the discharge side. Where other discharge flange orientations are required, their suitability must be determined at the ordering and layout design stage.

The diameter, routing and connections of the suction line must be designed taking into account inlet losses, air accumulation and the flow conditions at the pump inlet.

02

Multistage operating principle

The impellers on the same shaft add energy to the liquid in successive stages. The diffusers guide the flow leaving the impeller to the next stage and help to convert part of the velocity energy into pressure.

The heads generated by the stages add up. Increasing the number of stages mainly increases the head; the flow does not rise in proportion to the number of stages.

The flow and total head of the pump depend on the operating point defined by the pump curve and the system curve.

03

Ring-section casing and maintenance

The suction, stage and discharge casings are joined at planes perpendicular to the shaft axis. This construction is called a radially split ring-section casing.

Inspection or replacement of stage elements, impellers and diffusers follows the dismantling and assembly sequence of the model concerned.

This arrangement is not the same as the axially split casing of double suction pumps. Maintenance access and the connections that have to be removed are assessed according to the construction of the model and the plant layout.

04

Bearings and lubrication

In the reference design, a grease-lubricated rolling bearing is used on the drive side. The plain bearing on the suction side is lubricated by the pumped liquid.

For the plain bearing to work, liquid of suitable quality must reach the bearing. Filling the pump with liquid, venting it and preventing dry running are therefore important.

The bearing type, shaft arrangement and permissible loads can vary with pump size, speed and number of stages. Lubrication and maintenance must follow the operating instructions of the model concerned.

05

Impellers and axial thrust balancing

In the reference design with balancing holes in the impellers, the pressure distribution between the front and back shrouds of the impeller is adjusted to reduce the axial hydraulic thrust.

The remaining axial loads are taken up by a suitable bearing arrangement. Axial forces are not eliminated entirely, and the bearing load varies with the operating point.

The balancing arrangement is assessed according to the technical documentation of the selected model.

06

Number of stages and mechanical limits

The number of stages is selected taking into account the required head together with shaft strength, shaft material, speed, motor power and the permissible casing pressure.

For the same hydraulic size, the maximum permissible number of stages can vary with speed and shaft material. The general upper speed limit of the series does not apply to every size and stage combination.

Final selection is made from the relevant performance curves and model tables.

07

Shaft sealing and temperature

Shaft sealing is determined by the properties of the liquid and the operating temperature and pressure.

In the reference design with soft packing, applications up to 110 °C and those in the 110–140 °C range are assessed differently. In the upper temperature range a cooled stuffing box is used.

A mechanical seal option can also be considered on suitable models. Seal faces, elastomers and any auxiliary cooling or flushing requirements are selected according to the application.

The +140 °C limit does not mean that every material and sealing combination can be used at this temperature.

08

Direction of rotation and drive selection

The direction of rotation is defined as viewed from the motor. The direction of rotation of the pump is anticlockwise.

The drive unit must be selected to match the required direction of rotation and speed of the pump. Before commissioning, the motor connections and the direction-of-rotation mark on the pump must be checked.

Because of this direction of rotation, pumps in the standard arrangement cannot be driven by a diesel engine. If another drive unit is being considered, its suitability must be assessed separately for the pump and drive arrangement concerned.

09

Casing pressure and flanges

PN16 flange connections are used on the suction side and, depending on the selected arrangement, PN40 or PN63 on the discharge side.

The flange pressure class is not the same concept as the permissible casing pressure of the pump. When checking casing pressure, the suction pressure and the pressure rise generated by the pump at closed valve are taken into account together.

The density of the liquid must be taken into account when converting head into pressure. The permissible operating conditions are checked together with the casing material, temperature and sealing arrangement.

10

Material options

The suction, stage and discharge casings, impellers, diffusers, shaft, sleeves, plain bearing and sealing elements are selected to be compatible with the liquid.

For suitable parts and models, materials such as cast iron, ductile iron, cast steel, bronze and stainless steel can be considered. The exact material combination is stated in the technical data of the selected pump.

The plain bearing material and running clearances must suit the conditions of lubrication by the liquid.

11

Impeller balancing and installation

The impellers are balanced to the specified ISO 21940-11 G 6.3 balancing grade.

Smooth mechanical running is affected by impeller balance together with coupling alignment, foundation and anchoring, the condition of the bearings and pipe loads. The pipework must be supported independently and connections must not be forced onto the pump.

12

Pump selection and suction conditions

In addition to flow and head, selection takes into account liquid temperature, suction pressure, line losses, motor power and the operating range.

The NPSH available from the installation must exceed the NPSH required by the pump by a suitable safety margin. In hot liquids in particular, the rise in vapour pressure affects the suction conditions.

An end suction arrangement does not mean that the pump is self-priming. The pump must be filled and vented in accordance with the operating instructions.

Technical summary

Operating ranges and model range

The charts show the design range of the series. For a specific operating point, the hydraulics are verified by CFD analysis and delivered together with the performance curve sheet, dimensions and, where required, a test report.

9hydraulic types
including narrow impeller types
DN 40 – 150discharge flange
1450 / 2900rpm · 50 Hz
400 m³/hmaximum flow · head up to 450 m

The values given are the general operating limits of the series. The maximum flow, head, speed, temperature and pressure values do not all apply at the same operating point. The pump type, number of stages, materials and sealing arrangement are selected according to the liquid properties and operating conditions.

General selection chartHorizontal Multistage Centrifugal Pumps (End Suction), n = 1450 rpmQ [m³/h] – H [m]Swipe sideways for a closer look
General selection chartHorizontal Multistage Centrifugal Pumps (End Suction) · Narrow impellers, n = 1450 rpmQ [m³/h] – H [m]Swipe sideways for a closer look
General selection chartHorizontal Multistage Centrifugal Pumps (End Suction), n = 2900 rpmQ [m³/h] – H [m]Swipe sideways for a closer look
Model listGMS-E · 9 hydraulic types · by discharge flange · with maximum number of stages

1450 rpm (5)1450 and 2900 rpm (4).1narrow impeller type

DN 401 type
401450: 13 · 2900: 12
DN 501 type
501450: 12 · 2900: 10
DN 651 type
651450: 11 · 2900: 7
DN 801 type
801450: 11 · 2900: 4
DN 1002 types
1001450: 9100.11450: 9
DN 1252 types
1251450: 7125.11450: 7
DN 1501 type
1501450: 5
MaterialsMaterial options and equivalents
Material options

StandardOptional—Not specified

Swipe sideways to see the full table
MaterialMaterial no.Suction casingDis­charge casingStage casingDiffuserImpellerShaftBearing housingWear ringInter­medi­ate sleeveGland sleeveStage sleevePlain bearing
Cast materials
Grey cast iron0.6025—————
Ductile cast iron0.7040—————
Ductile cast iron · low temperature0.7043—————
Cast steel1.0619——————————
Cr-Ni stainless cast steel1.4308—————
Cr-Ni stainless cast steel · low carbon1.4309—————
Cr-Ni-Mo stainless cast steel1.4408—————
Cr-Ni-Mo stainless cast steel · low carbon1.4409—————
Austenitic cast steel1.4500——————
Duplex stainless cast steel1.4517——————
Super duplex stainless cast steel1.4469——————
Martensitic stainless cast steel1.4317——————
Martensitic stainless cast steel1.4008——————
Tin bronze2.1050.01——————
Nickel-aluminium bronze2.0975.01—————————
Leaded bronze2.1096.01—————————
Steel materials and heat treatment options
Carbon steel1.0503—————————
Martensitic stainless steel1.4021————————
Martensitic stainless steel · quenched and tempered1.4021 + QT————————
Cr-Ni stainless steel1.4301————————
Cr-Ni-Mo stainless steel · low carbon1.4404————————
Duplex stainless steel1.4460———————————
Duplex stainless steel1.4462————————
Polymer materials
PolytetrafluoroethylenePTFE———————————

Suitable for mechanical seals of different types and makes.
Cr: Chromium · Ni: Nickel · Mo: Molybdenum · QT: Quenched and tempered.

Material equivalents
Swipe sideways to see the full table
Material descriptionMaterial no.EN / DIN designationAISI / SAE / ASTM equivalent*
Grey cast iron0.6025EN-GJL-250 (GG25)A48 Class 40B
Ductile cast iron0.7040EN-GJS-400-15 (GGG40)A536 60-40-18
Ductile cast iron · low temperature0.7043EN-GJS-400-18-LT (GGG40.3)A536 60-40-18
Cast steel1.0619GP240GH (GS-C25)A216 WCB
Cr-Ni stainless cast steel1.4308GX5CrNi19-10A351 CF8
Cr-Ni stainless cast steel · low carbon1.4309GX2CrNi19-11A351 CF3
Cr-Ni-Mo stainless cast steel1.4408GX5CrNiMo19-11-2A351 CF8M
Cr-Ni-Mo stainless cast steel · low carbon1.4409GX2CrNiMo19-11-2A351 CF3M
Austenitic cast steel1.4500GX7NiCrMoCuNb25-20A351 CN7M
Duplex stainless cast steel1.4517GX2CrNiMoCuN25-6-3-3A890 CD4MCuN
Super duplex stainless cast steel1.4469GX2CrNiMoN26-7-4A890 CE3MN
Martensitic stainless cast steel1.4317GX4CrNi13-4A352 CA6NM
Martensitic stainless cast steel1.4008GX7CrNiMo12-1A217 CA15
Tin bronze2.1050.01G-CuSn10B427 C90700
Nickel-aluminium bronze2.0975.01G-CuAl10NiB148 C95500
Leaded bronze2.1096.01G-CuSn5ZnPbB584 C83600
Carbon steel1.0503C45AISI 1045
Martensitic stainless steel1.4021X20Cr13A276 Type 420
Martensitic stainless steel · quenched and tempered1.4021 + QTX20Cr13 + QTA276 Type 420 + QT
Cr-Ni stainless steel1.4301X5CrNi18-10A276 Type 304
Cr-Ni-Mo stainless steel · low carbon1.4404X2CrNiMo17-12-2A276 Type 316L
Duplex stainless steel1.4460X3CrNiMoN27-5-2AISI 329
Duplex stainless steel1.4462X2CrNiMoN22-5-3UNS S32205

* Equivalents are for reference only; materials to different standards may not be identical in every chemical, mechanical and heat treatment requirement. The relevant product standard and material certificate govern the final selection.

For manufacturers

GMS-E design package

A horizontal, end suction, diffuser-type multistage pump series. From hydraulic design to pattern drawings and test verification: the design foundation a manufacturer needs to produce under its own brand.

WHAT THE PACKAGE INCLUDES

01Hydraulic design

Impeller and diffuser 3D models, performance curve sheets for the models of the series. Parametric 3D models prepared in Siemens NX and SolidWorks.

02Mechanical design

Dimension drawings, assembly and sectional drawings, parts list. Stress, vibration and fatigue assessments of shaft, impeller and casing components.

03Materials and standards

Material options and equivalents, flange dimensions. EN 1092-2 / PN16 suction and EN 1092-2 / PN40–PN63 discharge flanges, ISO 21940-11 G 6.3 impeller balancing.

04Verification

Comparison of design and test results using ANSYS CFX / Fluent-based CFD analyses; test and verification reports depending on project scope.

05Scope of delivery

Manufacturing drawings, casting pattern and core data, manufacturing documentation. Work is carried out on a project basis or under an ongoing outsourced R&D model.

For your company, outsourced R&D

With more than 25 years of pump and turbomachinery experience, we take on your company’s R&D and new product development projects. We complement your production capacity with engineering support that extends from design to production.